Size process and utility lines from mass flow and density: API RP 14E erosional velocity Ve=1.22·C/sqrt(rho), recommended service-velocity bands (pump suction/discharge, gas, steam, two-phase), the rho-v-squared momentum index, and the smallest standard DN that keeps velocity in range.

Inputs

ParameterNotes
Mass flow W (kg/h)Operating mass flow
Density (kg/m3)At flowing conditions
Service typeSets the recommended velocity band
API 14E C-factor100 continuous / 125 intermittent
Existing ID (optional)Rates an existing line

Outputs

OutputBasis
Erosional velocity VeAPI RP 14E, 1.22·C/sqrt(rho)
Recommended velocity & IDService band, capped below Ve
Recommended DNSmallest standard size
rho-v-squared & % of VeErosion/vibration screen

Standards & Method

Erosional velocity per API RP 14E (SI form Ve=1.22·C/sqrt(rho)). Practical velocity bands: pump suction 0.6-1.5, discharge 1.5-3, gas/vapor 15-30, steam 20-40 m/s; rho-v-squared guideline below 5000 single-phase / review above 10000. A reducer/expander K=f(beta,angle) helper (Crane TP-410) is built in.